Wind Ventilators, Air, Turbo, Roof Turbine Ventilators, Mumbai, India

Melt Flow Index Tester

Computerized Melt flow index tester
As per ASTM D 1238 & ISO 1133 – (Test Method A & B) to check the melt flow rate (MFR) & melt volume rate (MVR) of thermoplastics and compounds with automatic result.

Specification:
Microcontroller with alpha numeric key pad having built-in temperature controller with temperature range up to 400 degree centigrade, resolution of 0.1 degree Centigrade and accuracy of +/- 0.1 degree Centigrade similarly built-in timer with range 999.9 seconds.

Piston Travel: Up to 25 mm & resolution of 0.02 mm.
Specimen cutting: Motorized.
Specimen Weighing : Automatic up to 60 gm and resolution of 1 mg.
Weight : 0.325 kg, 1.2 kg, 2.16 kg, 3.8 kg, 5 kg & 21.6 kg hard chrome plated weights.
Digital Display: Individual MFI, MVR, Melt Density results & average results.
PC output : Through serial port with Window 7 compatible software.
Accessories : Standard accessories *.
Paint : Powder Coated.
Power Supply : 230 Volts, 50 Hz, Single Phase.

Standard accessories includes Orifice, Piston, Spoon, Spanner, Plumb line, Funnel, Material charger, Mirror, Tweezer, Orifice cleaner, Barrel cleaner, Sample cutter and Accessory stand.
   

Melt Flow Index Tester (KAYJAY/2006/AC)
Specification:
Temperature controller : Micro processor based PID controller with temperature range from ambient to 400ºC, resolution of 0.1ºC and accuracy of + 0.1ºC.

Timer : Digital presettable with a range up to 59 minutes, 59 seconds.
Sample cutting: Auto [Motorized]
Weights : 1.2 kg, 2.16 kg, 3.8 kg, 5 kg & 21.6 kg.
Accessories : Standard accessories *
Paint : Powder coated.
Power : 230 Volts, 50 Hz, single phase.

Standard accessories includes Orifice, Piston, Spoon, Spanner, Plumb line, Funnel, Material charger, Mirror, Tweezer, Orifice cleaner, Barrel cleaner, Sample cutter and Accessory stand.
 
MFI Tester For Film Testing (KAYJAY/ 2005/CE)

Specification:

Temperature controller : Micro processor based auto tuned PID controller with temperature range from ambient to 400ºC, resolution of 0.1ºC and accuracy of + 0.1ºC.

Timer : Digital presettable with a range up to 999 seconds and having buzzer output.
Sample cutting : Manual.
Weights : 2.16 kg & 5 kg.
Accessories : Standard accessories*
Paint : Powder coated.
Power : 230 Volts, 50 Hz, single phase.

Standard accessories includes Orifice, Piston, Spoon, Spanner, Plumb line, Funnel, Material charger, Mirror, Tweezer, Orifice cleaner, Barrel cleaner, Sample cutter and Accessory stand.
 
Melt Flow Index Tester For Polymer Testing (KAYJAY/1994/L)

Specification:

Temperature controller : Micro processor based auto tuned PID controller with temperature range from ambient to 400ºC, resolution of 0.1ºC and accuracy of + 0.1ºC.

Timer : Digital presettable with a range up to 999 seconds and having buzzer output.
Sample cutting : Manual.
Weights : 2.16 kg & 5 kg.
Accessories : Standard accessories *
Paint : Powder coated.
Power : 230 Volts, 50 Hz, single phase.

 
Computerized Melt flow index tester ASTM D 1238 & ISO 1133 (Test Method A)

Specification:
Microcontroller with alpha numeric key pad having built-in temperature controller with temperature range up to 400 degree centigrade, resolution of 0.1 degree Centigrade and accuracy of +/- 0.1 degree Centigrade similarly built-in timer with range 999.9 seconds.

Specimen cutting : Motorized.
Specimen Weighing : Automatic up to 60 gm and resolution of
1 mg.
Weight : 1.2 kg, 2.16 kg, 3.8 kg, 5 kg & 21.6 kg hard chrome plated Weights.
Digital Display : Individual MFI result with average results facility.
PC output : Through serial port with Window 7 compatible software.
Accessories : Standard accessories*.
Paint : Powder Coated.
Power Supply : 230 Volts, 50 Hz, Single Phase.

Standard accessories includes Orifice, Piston, Spoon, Spanner, Plumb line, Funnel, Material charger, Mirror, Tweezer, Orifice cleaner, Barrel cleaner, Sample cutter and Accessory stand.